GB18580-2001 “Formaldehyde emission in wood-based panel and relevant products”
GB18584-2001 “Limit to harmful substances of interior decoration materials wood furniture”
GB18587-2001 “Release limits to harmful substances of interior decoration materials carpets, carpet linings and carpet adhesives”
ASTM D6007-02 “Standard test method of small size environmental test chamber for formaldehyde concentration in wood VOC Emission Chamber for Automotive Interior products release gas”
EN717-1 “Environmental test chamber for wood-based panel formaldehyde emission”
EN13419-1 “Environmental test chamber for VOCs released from construction products – Part one method for release test of environmental test chamber”
HJ 571-2010 “Technical requirement for environmental labeling products – wood based panels and finished products”
HJ566-2010 “Technical requirement for environmental labeling products – wooden toys”
Upholstered Furniture Limits of Harmful Substances from Sofa (Exposure Draft) and Climate Chamber for Detection of Volatile Organic Compounds in Furniture (Exposure Draft).
LY/T 1980-2011 Determination Device of the Emission of Volatile Organic Compounds and Formaldehyde
LY/T 1981-2011 Testing Apparatus for Formaldehyde Emission by the Gas Analysis Method.
LY/T 1982-2011 Large Chamber for Formaldehyde Emission of Wood-based Panels and Its Products.
Model: Formaldehyde Emission Chamber | LY1001-N02 | LY1001-N1 | ||
Nominal Volume (L) | 225(1±2%) | 1000(1±2%) | ||
Internal Dimension (mm) |
W | 550 | 850 | |
D | 600 | 1080 | ||
H | 680 | 1100 | ||
External Dimension★ (mm) |
W | 1100 | 1460 | |
D | 796 | 1285 | ||
H | 1520 | 1572 | ||
Character | Temperature Range | 15~30 ℃ | ||
Humidity Range | 35~70 % RH | |||
Temperature Deviation | ≤ ±0.5 ℃ | |||
Humidity Deviation | ≤ ± 2% RH | |||
Temperature Uniformity | ≤±0.8 ℃ | |||
Humidity Uniformity | ≤ ±2 % RH | |||
Temperature Fluctuation | ≤ ±0.5 ℃ | |||
Humidity Fluctuation | ≤ ±2 % RH | |||
Air Exchange Rate | 0~1.5 t/h | |||
Sealing | Cabin Air Leakage Rate <5% × Gas Supply Rate or 1kPa Overpressure, Gas Leakage Less ThanCapacity * 1 ‰ m³/ min | |||
Central Wind Speed | 0.1~1.0 m/s(Continuously Adjustable) | |||
Relative Positive Pressure | 10±5 Pa | |||
Rate of Recovery | >90 % | |||
Background Concentration | Methanol:≤0.006 mg/m3 | |||
Temperature Control Method | Indirect Temperature Control Method of Water Circulation | |||
Humidity Control Method | Dry Gas and Moisture Ratio Two-way Adjustment Method | |||
Material | Shell | Q235A Cold Rolled Steel 1.5mm,Surface Electrostatic Spraying,White | ||
Inner Cabin | SUS304 Mirror Stainless Steel 1.5mm(8k Mirror) | |||
Thermal Insulation | Polyurethane Foam+XPS | |||
Sealing | Silicon Gel(Food Grade)、PTFE | |||
Operation | Monitor | 7-inch Color Touch Screen,Resolution 800×480,Remote Connection (optional) | ||
Automatic Recording of Items | Temperature, Humidity, Pressure (optional), Flow Rate (optional), Running Time, Fault Record | |||
Control Method | Temperature Control: Proportional, Integral, Differential (P.I.D); System Control:PLC+HMI | |||
Resolution | Temperature:0.1 ℃;Humidity:0.1 % RH | |||
Communication Interface | USB-A,1 pcs; USB-B,1 pcs; RS232,1 pcs; RS485,1 pcs; RJ-45 1 pcs(Optional) | |||
Storage and Recording Function | RAM;U Disk;SD Card | |||
Hydration Water Quality, Cycle | Distilled Water;>30 Days(Continuous Operation) | |||
Power | AC380(1±10%)V (50±0.5)Hz Three-phase Four-wire+Ground Wire Protection | |||
Installed Capacity(Kw) | 2.5 | 3 | ||
Weight(Kg) | 280 | 320 | ||
Noise(dB) | ≤60 dB | |||
System Protection | High and Low Voltage Protection, Over-current Protection of Refrigeration System; Over Temperature Protection; Motor Over-current Protection; Water Shortage Protection; Power Supply Phase Loss, Phase Sequence Protection, etc. |
Small Temperature Difference Water Bath Temperature Control Technology
Dry Moisture Ratio Patented humidity Control Technology
Two-way Adjustment of Fast Balance Humidity
Temperature and humidity PID automatic balance
Automatic Recording of Pressure and Flow
Automatic Data Transfer, Permanent Storage
Modular Design and Easy Maintenance
Energy-saving Design, Green and Environmental Protection
Operating Power as Low as 1.5kw
Noise is Less Than 60 Decibels